Precautions for installation of diaphragm coupling

Time: 2012-05-20 16:07 Author: XINLAN Coupling Click:
Precautions for installation of diaphragm coupling

Diaphragm couplingThe installation precautions have the following points
①. Products with diaphragms have edges and may cause injuries. It is recommended to wear thick gloves when installing.
②. Please install a protective cover and other devices around the coupling to ensure safety.   
③. When the shaft center deviation exceeds the allowable value during installation, the coupling may be deformed, resulting in damage or shortened service life.   
④. The allowable shaft deviation of the coupling includes radial, angular, and axial deviation. When installing, please make adjustments to ensure that the shaft deviation is within the allowable range of the corresponding product catalog.   
⑤ When multiple deviations appear at the same time, the corresponding allowable value should be halved.   
⑥. In order to prolong the service life of the coupling, it is recommended to set the shaft deviation within 1/3 of the allowable value. ⑦. Tighten the screw after inserting the mounting shaft, otherwise it will cause the coupling to deform. When tightening the screw, Please use a torque wrench and do not use screws other than the accessories for installation.   
⑧. If there is an abnormal sound during operation, please stop the operation immediately, and check the installation accuracy, screw looseness, etc. separately. It is recommended to leave the screw outside the screw after installation and debugging.